TM10-5430-229-13&P
4-12.
END PANEL ASSEMBLIES REPAIR.
This Task Covers:
a. Disassembly
b. Cleaning
c
Inspection
d. Repair
e Assembly
Initial Setup:
Tools Required
Tool Kit, General Mechanic's (Appendix B, Item 1)
Material's Required
Cloth, Lint-Free (Appendix F, Item 1)
Brush, Medium Bristle (Appendix F, Item 2)
Solvent, Dry Cleaning (Appendix F, Item 3)
Equipment Condition
Top cover assembly removed from storage chest (see paragraph 2-8)
End panel assembly removed from tank storage chest (see paragraph 2-8)
NOTE
The WTSC has two identical end panel assemblies. This maintenance paragraph contains the
procedures for the repair of one of these panels.
a.
Disassembly. (Refer to Figure 4-3.)
(1) Remove cross pin (1) from turnlock (2)
(2) Remove turnlock (2) and washer (3) from end panel assembly (4).
(3) Remove gasket material (5), if defective.
b. Cleaning.
(1) Remove all build up of dirt, oil, and debris from all metal surfaces
WARNING
Serious injury can result in breathing fumes of dry cleaning solvent A-A-711. Serious injury or
death can result from explosion of fumes from solvent When using this solvent:
Clean parts in a well ventilated area.
Avoid inhalation of solvent fumes and prolonged exposure of
kin to cleaning solvent Wash exposed skin thoroughly.
Do not use near open flame or excessive heat. Flash point of
solvent is 100° F to 138° F (38 C to 59° C)
Wear eye protection when blowing solvent from parts. Air pres-
sure should not exceed 30 psig (2.1 kg/cm2).
4-8