TM 10-5430-243-12&P
0008 00
Change 1
0008 00-2
CORRECTIVE ACTION
If gaskets installed in filler/discharge fittings are damaged,
replace gaskets and screws as necessary. See WP 0015 00.
MALFUNCTION
Make sure dust plug/cap are securely installed on filler/discharge fittings and that
cam-lever coupling arms are secured.
CORRECTIVE ACTION
Tighten as necessary or notify unit maintenance for repair.
TROUBLESHOOTING PROCEDURE
VENT FITTING ASSEMBLY
SYMPTOM
Vent fitting assembly leaks.
MALFUNCTION
Inspect for gasket leakage at cam lock lever coupling and flanged adapter.
CORRECTIVE ACTION
Reseal or tighten cam lock lever coupling arms.
Replace cam lock lever coupling dust cap gasket. Refer to
WP 0014 00.
Vent fitting assembly continues to leak.
CORRECTIVE ACTION
If leak continues, notify Unit Maintenance.
MALFUNCTION
Check cam lock lever coupling for cracks or breaks. Check for loose or missing
hex-head screws.
CORRECTIVE ACTION
If leak continues, notify unit maintenance.
CAUTION
To prevent damage to water tank, the following malfunctions should only be
performed when tank is empty.
MALFUNCTION
Check for dirt, bits of gravel and debris on vent relief cap seal.