TM 10-5430-243-12&P 0008 00 Change 1 0008 00-2 CORRECTIVE ACTION If gaskets installed in filler/discharge fittings are damaged, replace gaskets and screws as necessary. See WP 0015 00. MALFUNCTION Make sure dust plug/cap are securely installed on filler/discharge fittings and that cam-lever coupling arms are secured. CORRECTIVE ACTIONTighten as necessary or notify unit maintenance for repair. TROUBLESHOOTING PROCEDURE VENT FITTING ASSEMBLY SYMPTOM Vent fitting assembly leaks. MALFUNCTIONInspect for gasket leakage at cam lock lever coupling and flanged adapter. CORRECTIVE ACTION Reseal or tighten cam lock lever coupling arms. Replace cam lock lever coupling dust cap gasket. Refer to WP 0014 00. Vent fitting assembly continues to leak. CORRECTIVE ACTION If leak continues, notify Unit Maintenance. MALFUNCTION Check cam lock lever coupling for cracks or breaks. Check for loose or missing hex-head screws. CORRECTIVE ACTION If leak continues, notify unit maintenance. CAUTION To prevent damage to water tank, the following malfunctions should only be performed when tank is empty. MALFUNCTION Check for dirt, bits of gravel and debris on vent relief cap seal.