TM 10-5430-243-12&P
0008 00
0008 00-5
Change 1
CORRECTIVE ACTION
If hardware is loose or missing, notify Unit Maintenance.
If female quick-disconnect coupling gasket is damaged or
missing, replace gasket. Refer to WP 0012 00.
MALFUNCTION
Inspect the flange gasket for damage or leaks.
CORRECTIVE ACTION
If damaged, notify Unit Maintenance.
Inspect the male flanged adapter for missing or loose hex-head cap screws, hex
nuts, washers, and lockwashers.
CORRECTIVE ACTION
If damaged or loose hardware, notify Unit Maintenance.
Male flanged adapter gasket leaks between gasket and valve.
CORRECTIVE ACTION
If leaking, notify Unit Maintenance.
TROUBLESHOOTING PROCEDURE
FILLER/DISCHARGE BALL VALVE ASSEMBLY (RELIANCE AND MPC MODELS)
SYMPTOM
Ball valve assembly leaks.
MALFUNCTION
Check that the ball valve is closed completely.
CORRECTIVE ACTION
Close ball valve and tighten securely.
If coupling gasket is damaged or missing, replace gasket. See
WP 0013 00.
Inspect the ball valve for damage or wear.
CORRECTIVE ACTION
If damaged or worn, notify Unit Maintenance.
Inspect the ball valve for proper alignment.