TM 10-5430-243-12&P 0008 00 0008 00-5 Change 1CORRECTIVE ACTION If hardware is loose or missing, notify Unit Maintenance. If female quick-disconnect coupling gasket is damaged or missing, replace gasket. Refer to WP 0012 00. MALFUNCTIONInspect the flange gasket for damage or leaks. CORRECTIVE ACTIONIf damaged, notify Unit Maintenance. Inspect the male flanged adapter for missing or loose hex-head cap screws, hex nuts, washers, and lockwashers. CORRECTIVE ACTIONIf damaged or loose hardware, notify Unit Maintenance.Male flanged adapter gasket leaks between gasket and valve. CORRECTIVE ACTIONIf leaking, notify Unit Maintenance. TROUBLESHOOTING PROCEDURE FILLER/DISCHARGE BALL VALVE ASSEMBLY (RELIANCE AND MPC MODELS) SYMPTOM Ball valve assembly leaks. MALFUNCTION Check that the ball valve is closed completely. CORRECTIVE ACTION Close ball valve and tighten securely. If coupling gasket is damaged or missing, replace gasket. See WP 0013 00. Inspect the ball valve for damage or wear. CORRECTIVE ACTION If damaged or worn, notify Unit Maintenance. Inspect the ball valve for proper alignment.