TM 10-5430-243-12&P 0009 00 0009 00-1 Change 1 – 28 April 2002 OPERATOR AND UNIT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TANK, FABRIC, COLLAPSIBLE, WATER STORAGE, 20,000 AND 50,000 GALLONS UNIT TROUBLESHOOTING PROCEDURES INTRODUCTION TO UNIT TROUBLESHOOTING The Troubleshooting Procedures section lists the common malfunctions which you may find during the operation or maintenance of the collapsible fabric water tank assembly or its components. Perform the inspections and corrective actions in the order listed in the troubleshooting section. This manual cannot list all malfunctions that may occur, nor all inspections and corrective actions. If a malfunction is not listed or is not corrected by listed corrective actions, notify supervision. WARNING To prevent possible injury, read all warnings in the front of this manual before troubleshooting.CAUTION To prevent possible flooding, drain the tank partially before attempting to inspect or replace gaskets or seals. TROUBLESHOOTING PROCEDURE WATER TANK SYMPTOM Tank body leaks. MALFUNCTION Check tank for cuts, tears, punctures or damaged seams. CORRECTIVE ACTION Perform emergency repairs using wood plugs or sealing clamps. Refer to WP 0006 00. If leak cannot be repaired, immediately notify supervision. TROUBLESHOOTING PROCEDURE VENT FITTING ASSEMBLY SYMPTOM Vent fitting assembly leaks. MALFUNCTIONInspect for gasket leakage between the quick-disconnect coupling and flanged adapter.