Precisionâ Instruction Manual
SERVICE (Contd.)
HEATER DATA
Heater
Resistance
Cat. No. Model Wattage Voltage (Ohms)
66630
180
225
120
64
66557
181
225
120
64
66564
181
225
240
256
66643
182
300
120
48
66617
182
300
240
192
66551
183
400
120
36
66553
183
400
240
144
66648
184
600
120
24
66618
184
600
240
96
66562
185
600
120
24
66563
185
600
240
96
66634
186
2(600)
120
24
66647
186
2(600)
240
96
66552
188
2(400)
120
36
66554
188
2(400)
240
144
Heater Resistance Procedure:
WARNING: Disconnect the bath from its power source.
Refer to the appropriate wiring diagram and the table above for resistance values at room temperature. Resistance is
measured between terminals on the heater element.
Be sure to disconnect at least one lead of each heater before taking an ohmmeter reading.
If the heater is open (infinite resistance), it should be replaced.
Heater Replacement:
WARNING: Service should be performed by qualified service personnel.
-7-