Table 4-1. Organizational Maintenance Troubleshooting - Continued
Table 4-1. Organizational Maintenance Troubleshooting - Continued - TM-10-8110-202-13P_56
TM-10-8110-202-13P Drum Fabric Collapsible Drinking Water 500 Gallon Capacity Model RD-610 (NSN 8110-01-122-0015) Manual
Page Navigation
33
34
35
36
37
38
39
40
41
42
43
TM 10-8110-202-13 & P
Table 4-1. Organizational Maintenance Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. DAMAGED HANDWHEEL
Step 1.
Check condition of hand-
wheel (11).
Replace handwheel if
damaged or cracked.
5. LEAKAGE THROUGH ADAPTER ASSEMBLY
Step 1. Check condition of adapter assembly (2).
Replace adapter assembly (2).
6. LEAKAGE AROUND OUTSIDE OF ADAPTER ASSEMBLY
Step 1. Check adapter assembly (2) for looseness.
Tighten adapter assembly (2).
Step 2. Leakage continues.
Replace adapter assembly (2).
Step 3. Leakage continues.
Notify next higher level of maintenance.
4-9