TM 10-8110-202-13 & P
Table 4-1. Organizational Maintenance Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. LIQUID HAS UNUSUAL ODOR
The drum is authorized to be filled only
with drinking water.
Use of the drum for
any other liquid may cause sickness or
death of crewmembers.
If it has been determined during PMCS (Table 2-1) that the drum has been
used with any liquid other than drinking water, or if it is suspected that
the drinking water may be contaminated, empty contents of drum and
notify next higher level of maintenance.
2. DRINKING WATER IS LEAKING FROM OR AROUND COUPLER VALVE
Step 1.
Locate source of coupler valve leak.
a. Water leaks from coupler valve-to-adapter assembly connection.
1.
2.
3.
4.
Make sure coupler valve (1) is properly locked and installed in place.
If leakage continues, remove coupler valve from adapter assembly. If
water is leaking from adapter assembly, replace adapter assembly.
If adapter assembly is not leaking, replace gasket (3) on coupler valve (1),
Reinstall coupler valve onto adapter assembly (2).
If leakage continues, replace coupler valve (1) and send leaking coupler
valve to next higher level of maintenance.
4-7