TM 5-3825-226-24
TORQUE CONVERTER
(1)
Torque for bolts that hold impeller
to turning housing ................................ . 20 + 1 lb. ft. (27 ± 1 N-m)
(2)
Clearance between turbine and turning housing:
Across the diameter ....................020 to .040 in. (0.51 to 1.02 mm)
Maximum permissible clearance:
Across the diameter ................................ ........... 045 in. (1.14 mm)
Running ................................ ........................... 0225 in. (0.57 mm)
(3)
Torque for bolts that hold retainer
to turning housing ................................ ..36 ± 2 lb. ft. (49 ± 3 N.m)
(4)
Torque for bolts that hold drive gear
for pump to impeller ............................... 20 1 lb. ft. (27 ± 1 N-m)
(5)
Torque for bolt that holds bearing on
output shaft ................................ ......... 81 ± 4 lb. ft. (110 ± 5 N-m)
(6)
Torque for the bolts that hold stator
to the converter housing .........................38 ± 2 lb. ft. (49 ± 3 N.m)
(7)
Torque for the bolts that hold stator
to the carrier ................................ ...........20 ± 1 lb. ft. (27 ± 1 N.m)
(8)
Torque for the bolts that hold flange
to the output shaft ................................ ..36 ± 2 lb. ft. (49 ± 3 N.m)
(9)
Gap in seal rings ........................ .005 to .015 in. (0.13 to 0.38 mm)
(10)
Clearance between stator and turbine:
Across the diameter .................... 012 to .018 in. (0.30 to 0.46 mm)
Running ................................ .......006 to .009 in. (0.15 to 0.23 mm)
Maximum permissible clearance:
Across the diameter ................................ ............030 in. (0.76 mm)
Running ................................ ............................. .015 in. (0.38 mm)
(11)
Clearance between stator and impeller:
Across the diameter ................... 009 to .015 in,. (0.23 to 0.38 mm)
Running ................................ ..0045 to .0075 in. (0.11 to 0.19 mm)
Maximum permissible clearance:
Across the diameter ................................ ............024 in. (0.61 mm)
Running ................................ .............................. 012 in. (0.30 mm)
(12)
Torque for bolts that hold retainer
to converter housing .............................. 36 ± 2 lb. ft. (49 ± 3 N-m)
1-38