TM 5-3825-229-14&P4-60. LINES AND FITTINGS (cont)b. Installation(cont).(20) Connect solenoid valve wires (2) to spade lugs (3) on harness wires. Slide looms (1) to cover wire connections.CAUTIONDo not start pump unless distributor pump is primed. Refer to para. 2-16 to prime pump.(21)Refer to para. 4-22 and connect battery cables.(22)Refer to para. 2-20 and fill water tank.(23)Refer to para. 2-6 and couple semitrailer to prime mover. Operate prime mover and pressurize airsystem.(24)Refer to para. 4-63 and install spray nozzles.(25)Refer to para. 4-64 and install angle discharge valve.(26)Refer to para. 2-16 through 2-23. Operate spray system and check water piping and air lines forleaks.4-61. SUCTION AND FILL BUTTERFLY VALVESTHIS TASK COVERS:a. Removalc.Assemblyb. Disassemblyd.InstallationINITIALSETUP:Equipment Materials Required:Tools Required:Pipe Sealant (Item 11, Appendix E)Nomenclature:Personnel Required: 2General MechanicsEquipment Conditions:Tool KitRefConditions1-10. b.(2)Air reservoirs drained2-14Engine shut off2-21Water tank draineda. Removal.(1) Remove eight nuts (1), washers (2) and screws (3) holding suction tee (4), suction butterfly valve (5) andsuction line (6) together. Remove suction valve (5).4-138