TM 5-3895-370-14&P4-146. ENGINE OIL PRESSURE LINE REPLACEMENT (CONT).(5)Remove hose (5) from oil pressure gage (10).b. Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.(1)Flush hoses with drycleaning solvent and dry with lint-free cloth.(2)Inspect hoses for holes, cracks, and deterioration.(3)Inspect fittings for worn threads and signs of leakage.(4)Replace all parts failing inspection.4-400
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business