TM 5-3895-370-14&P
c.
Cleaning/Inspection.
WARNING
· Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes
and do not breathe vapors. Keep away from heat or flame. Never smoke when using
solvent; the flash point for type I drycleaning solvent is 100°F (38°C) and for type II is
140°F (60°C). Failure to do so may result in injury or death to personnel. P-D-680
type III is a substitute for types I and II in this application. The flash point for type III
is 200°F (93°C).
· If personnel become dizzy while using cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or clothes, flush with cold water. If
solvent contacts eyes, immediately flush eyes with water and get immediate medical
attention.
(1)
Clean all metal parts with drycleaning solvent and brush.
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use
only
with
effective
chip
guarding
and
personal
protective
equipment
(goggles/shield, gloves, etc).
(2)
Dry all metal parts with rags or compressed air.
(3)
Inspect all parts for cracks, excessive wear, and
metal fatigue.
(4)
Replace all parts failing inspection.
d.
Assembly.
(1)
Install zerk fitting (23) on retainer plate (20).
(2)
Install support bushing (21) on bushing bracket
(22) with two retainer plates (19 and 20), four
screws (18), lockwashers (17), and nuts (16).
5-135