TM 5-5430-211-13 & P
3-4
SERVICE ON RECEIPT OF EQUIPMENT - CONTINUED
TABLE 3-1 - CONTINUED
REPAIR ITEMS
NO
ITEM
ACTION
13
Boxed Repair Kit
Present
composed of:
2 x Gaskets O Ring
Present
2 x Gaskets quick
Present
disconnect
Gasket 4 inch flange
Present
SECTION IV ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Table 3-2 lists the preventive maintenance checks and services which shall be performed at specified intervals by
organizational maintenance personnel. It includes and expands upon the preventive maintenance services performed by
operator/crew maintenance and included additional services which are allocated to organizational maintenance.
If your equipment does not perform as required, refer to Chapter 3, Section V - Troubleshooting for possible problems.
Report any malfunctions or failures on the proper DA Form 2404, or refer to DA PAM 738-750, The Army Management
Maintenance System (TAMMS).
The interval column of your PMCS table tells you when to do a certain check or service.
If the equipment must be kept in continuous operation, check and service only those items that can be checked and
serviced without disturbing operation. Make the complete checks and services when the equipment can be taken out of
service.
Leak definitions shall be classified as follows:-
CLASS
I
Seepage of water (as indicated by wetness or discoloration) not great enough to form drops.
CLASS
II
Leaks of water great enough to form drops but not enough to cause drops to drip or run from the
faulty area or form puddles.
CLASS
III
Leaks of water great enough to form drops that fall or run or collect in puddles near the faulty area.
3-6