• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Operator's Preventive Maintenance Checks and Services for 500 Gallon Water Drum - Continued
CHAPTER 5. MAINTENANCE INSTRUCTIONS

Special Tools List For Drum, Fabric, Collapsible, Drinking Water 500 Gallon Water Capacity Page Navigation
  54    55    56    57    58  59  60    61    62    63    64  
img
0011 00
TM 5-5430-248-13&P
Table 1. Operator's Preventive Maintenance Checks and Services for 500 Gallon Water Drum
(Continued)
ITEM  INTERVAL
ITEM TO BE
PROCEDURE
EQUIPMENT NOT
NO.
CHECKED OR
READY/AVAILABLE IF:
SERVICED
Check both ends of the drum for missing or
loose socketcap screws (31 screws per side).
Socketcap
Socketcap screws are
24
After
screws
loose or water is leaking.
Check both ends of the drum for
1. Binding swivel plate (1).
2. Damaged swivel plate lugs (2).
2
Swivel plate is immobile
rendering the drum
25
After
Swivel plate
untowable.
WARNING
The drum is only authorized to be filled
with DRINKING WATER. The drum is
designed and permanently labeled for use
with DRINKING WATER ONLY. Filling the
drum with any other liquid may cause
sickness or death to personnel.
Liquid from drum is not
26
After
Drum Assembly
water.
Check if drum has been used for non-water.
END OF WORK PACKAGE
0011 00-12


Privacy Statement
Press Release
Contact