B - Before
D - During
A - After
D - Daily
H - Hourly
ITEM
INTERVAL
ITEM
TO BE
PROCEDURES
CHECK FOR AND HAVE
REPAIRED OR ADJUSTED
EQUIPMENT
IS NOT READY/
NO.
B D A D
H
INSPECTED
AS NECESSARY
AVAILABLE IF
TM 55-1930-209-14&P-17
Table C-1. Preventive Maintenance Checks and Services for Workboat, Lifesaving, and
Firefighting Systems (Continued)
200 hrs
c.
Change air filter. Clean around air filter
housing. Loosen four clamps and remove
cover on air intake housing. Change filter
and install in reverse order. Make sure dirt
does not enter housing while changing filter.
200 hrs
d.
Change crankcase ventilation air filter.
Unscrew old filter and discard. Screw in
new filter.
200 hrs
e.
Turn off fuel valves:
1) Barge 1. Turn off both incoming and
return fuel line valves on portside
stern bulkhead above the Racor fuel
filter. These two shutoff valves are not
installed on Barges 2 and 3.
2)
Barges 2 and 3. Turn off fuel oil at
turnoff valves on top of fuel tank. Be
prepared for more fuel oil spills as fuel
in line drains out through filter mount-
ing.
200 hrs
f.
Change engine-mounted fuel filter (may
not be mounted on all workboat engines).
1) Unscrew old filter and discard. Avoid
fuel oil splashes and spills.
2) Check that contact surface in cover
Filter gasket
and filter gasket are clean and
damaged.
undamaged.
3) Carefully fill new filter with clean fuel
oil and screw on by hand until gasket
touches cover. Tighten no more than
another 1/2 turn.
200 hrs
g.
Change Racor fuel filter on stern bulk-
head.
1) Use T-handle on top of filter to
unscrew top.
2)
Inspect gasket. If reusable, clean and
retain. If not reusable, replace gasket.
3) Remove old filter element and discard.
4) Insert Racor replacement element
(Racor part 201 OSM, or military equiv-
alent) over center tube with a turning
motion.
5) Fill filter with clean fuel oil. Lubricate
gasket and T-handle O-ring with fuel
oil.
C-8