TM 9-2330-267-14&P
4-41. AIR FILTER MAINTENANCE (M149) (Cont).
c.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive
heat. The solvents flash point is 100°F-138°F (38°C-59°C). If you become dizzy
while using cleaning solvent, immediately get fresh air and medical help. If solvent
contacts eyes, immediately wash your eyes and get medical aid.
1.
Clean all components with dry cleaning solvent and inspect for damage.
2.
Replace any damaged components.
d.
ASSEMBLY
Install new filter element (8), spring washer (14), spring (13), new gasket (12), adapter (11), and plug (10) in
body (9).
e.
INSTALLATION
1.
Install two fittings (3) in air filter (4).
2.
Position air filter (4) on crossmember
3.
Connect two tubes (2) to air filter (4).
(7) and install U-bolt (1), two new Iockwashers (6), and nuts (5).
4-77