TM 9-2330-267-14&P4-41. AIR FILTER MAINTENANCE (M149) (Con’t).c.CLEANING AND INSPECTIONWARNINGDry cleaning solvent P-D-680 is toxic and flammable. Always wear protective gogglesand gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, andclothes, and DO NOT breathe vapors. DO NOT use near open flame or excessiveheat. The solvent’s flash point is 100°F-138°F (38°C-59°C). If you become dizzywhile using cleaning solvent, immediately get fresh air and medical help. If solventcontacts eyes, immediately wash your eyes and get medical aid.1.Clean all components with dry cleaning solvent and inspect for damage.2.Replace any damaged components.d.ASSEMBLYInstall new filter element (8), spring washer (14), spring (13), new gasket (12), adapter (11), and plug (10) inbody (9).e.INSTALLATION1.Install two fittings (3) in air filter (4).2.Position air filter (4) on crossmember3.Connect two tubes (2) to air filter (4).(7) and install U-bolt (1), two new Iockwashers (6), and nuts (5).4-77