TM 9-2330-267-14&PS e c t i o n I l l . O R G A N I Z A T I O N A L P R E V E N T I V E M A I N T E N A N C E C H E C K SA N D S E R V I C E S ( P M C S )PageParagraph TitleNumberGeneral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3General PMCS Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3Organizational Preventive Maintenance Checks and Services (PMCS), Table 4-1 . . . . . . . . . . . . . . . . . . . . .4-4Reporting Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3Service Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3Specific PMCS Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-44 - 7 . G E N E R A L .To ensure that the water tank trailer is ready for operation at all times,it must be inspected systematically so thatdefects can be detected and corrected before they result unserious damage or failure. Table 4-1 contains a tabulatedlisting of Preventive Maintenance Checks And Services (PMCS) topersonnel.be performed by organizational maintenance4-8. SERVICE INTERVALS.Perform PMCS, found in Table 4-1, at the following intervals:(1) Perform Quarferly (Q) PMCS once every three months.(2) Perform Semiannual (S) PMCS once every six months.(3) Perform Annual (A) PMCS once each year.4-9. REPORTING REPAIRS.Report all defects and corrective actions on DA Form 2404. If a serious problem is found, report it to yoursupervisor immediately.4-10. GENERAL PMCS PROCEDURES.WARNINGDry cleaning solvent P-D-680 is toxic and flammable. Always wear protective gogglesand gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, andclothes, and DO NOT breathe vapors. DO NOT use near open flame or excessiveheat, The solvent’s flash point is 100°F-138°F (38°C-59°C). If you become dizzywhile using cleaning solvent, immediately get fresh air and medical help. If solventcontacts eyes, immediately wash your eyes and get medical aid.a. Keep equipment clean. Dirt, oil, and debris may cover up a serious problem. Clean as you work and asneeded. Use dry cleaning solvent (Item 9, Appendix E) on all metal surfaces. Use soap (Item 8, Appendix E) and wateron rubber, plastic, and painted surfaces.b. While performing PMCS, inspect the following components:(1) Bolt, Nuts, and Screws. Ensure that they are not loose, missing, bent, or broken. Tighten any thatare loose.4-3
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business