TM 10-4130-237-145-25.THERMOSTATIC VALVE REPAIR (CONT)a. D i s a s s e m b ly1Remove four lower housing retaining bolts and lockwashers.2Separate lower housing from upper housing.3Remove seal from upper housing.4Remove temperature element assembly from upper housing.5Remove O-ring from temperature element assembly.b. Assembly1234567Lubricate O-ring and seal with a light coat of grease.Install O-ring on new temperature element assembly.Install temperature element assembly in upper housing.Install seal in upper body.Install lower housing on upper housing.Install four lower housing retaining bolts.Install thermostatic valve (para 5-24).5-80