TM 10-4320-346-1 2&P
4-17.
MISCELLANEOUS FITTINGS.
This Task Covers:
Repair
Initial Setup:
Tools Required
Tool Kit, General Mechanic's (Appendix B, Item 1)
Material's Required
Brush, Medium Bristle (Appendix F, Item 2)
Solvent, Dry Cleaning (Appendix F, Item 3)
Cloth, Lint-Free (Appendix F, Item 1)
Equipment Condition
Assembly removed from FAWPSS installation.
In addition to the other components listed in the previous chapters and paragraphs of this technical manual,
there are a number of various miscellaneous fittings and components which are furnished with the FAWPSS.
The following general maintenance procedures are to be used to verify that these additional miscellaneous
components are in proper working order.
a.
Clean.
(1)
Remove all build up of dirt, oil, and debris from all mating surfaces and clamping areas.
WARNING
DO NOT breath dry cleaning solvent vapors for long periods of time or allow
solvent to come into contact with skin for an extended time. DO NOT use solvent
near open flames or excessive heat.
(2) Clean all metallic parts with a clean soft cloth (Appendix F, Item 1) or a medium bristle brush
(Appendix F, Item 2), and cleaning solvent (Appendix F, Item 3).
(3) Allow parts to dry.
b.
Inspection.
(1) Inspect all metal parts for cracks, corrosion, or broken fittings.
(2) Examine all coupling half gaskets for cracks, tears, or nicks.
c.
Repair.
Repair is limited to replacement of parts found defective during inspection.
4-20