TM 10-4610-234-13
Common Name
2-Inch to 4-Inch Reducers . . . . . . . . . . . . . . . . . . . . .
2-Inch to 1-1/2-Inch Reducers . . . . . . . . . . . . . . . . .
1.7 LIST OF ABBREVATIONS.
K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40K WDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Official Nomenclature
Reducers,Female by Male Quick Disconnect
Cam-Locking, 2-Inch to 4-Inch Reducers
Reducers, Female by Male Quick Disconnect
Cam-Locking, 2-Inch to 1 -1/2-inch Reducers
Kilo (Thousand)
Assembly
40,000 Gallon Water Distribution System
Section II. EQUIPMENT DESCRIPTION
1.8
EQUIPMENT CHARACTERISTICS. CAPABILITIES AND FEATURES.
a.
(1) Portable
(2) Self contained
(3) Adaptable to meet different water supply demands
b. Capabilities and Features
(1) Easily and quickly set up in the field
(2) Needs no tools to set up
(3) Automatically chlorinates water at different flow rates
(4) Interchangeability of couplings and hoses increases reliability
(5) No outside power requirements needed
1.9 LOCATION AND DESCRIPTION OF SYSTEM COMPONENTS.
125 GPM PUMP CONNECTION KIT (1). Contains couplings, hoses, components necessary to connect 125
GPM pump to the water system.
125 GPM PUMP (2). Pumps water under pressure through the water system. Refer to TM 5-4320-304-14
or TM 10-4320-309-14 for additional pump information.
DUAL TANK CONNECTION KIT (3). Contains hoses, valves, and couplings needed to connect two 20,000
gallon water tanks to the system.
WATER TANKS (4). Store 20,000 gallons of potable water. Assume pillow shape when filled. Handles on
sides of tanks aid movement when tank is empty. When not in use, the tanks may be folded or rolled and
stored in the tank chest. The system is supplied with three 20K tanks. Two tanks are used during normal
setup, the third tank is a spare. Refer to TM 5-5430-226-12 for additional information on the water tank.
350 GPM PUMP CONNECTION KIT (5). Contains components necessary to connect the 350 GPM pump
to the water system.
350 GPM PUMP (6). Supplies water under pressure to the water system. Refer to TM 5-4320-226-14 for a
description of the 350 GPM pump.
WATER METER (7). Measures amount of water flow.
1-3
Characteristics