TM 10-4610-234-13
2.13 PREPARATION FOR MOVEMENT - continued.
g. Disassemble
Dual Tank Connection Kit.
(1) Disconnect all suction hoses, discharge hoses, tees, and gate valves from water tanks and 125
GPM pump (source) connection kit.
(2) Drain water from all components and allow to dry, Install protective caps and plugs.
(3) Prepare water tanks for movement in accordance with TM 5-5430-226-12.
h. Disasse mble 125 G PM Pump Connection Kit.
(1) Disconnect all discharge hoses, gate valves, check valve, reducers and 125 GPM pump from
water source.
(2) Drain water from all components and allow to dry. Install protective caps and plugs.
(3) Pepair 125 GPM Pump for movement in accordance with TM 5-4320-304-14 or TM
10-4320-309-14.
2.14 DECALS AND INSTRUCTION PLATES.
Instruction plates are used on the 40K Water Distribution System to advise the operator of proper operating
procedures. Stencils provide additional operating information and cautions to be observed during use of the
equipment. Decals and instruction plates appear on major assemblies of the 40K water system.
a. For decals and instruction plates on the 350 GPM pump, refer to TM 5-4320-226-14.
b. For decals and instruction plates on the 125 GPM pump, refer to TM 5-4320-304-14 or TM
10-4320-309-14.
c. For decals and instruction plates on the 20,000 gallon collapsible fabric tanks, refer to TM
5-5430-226-12.
d. For decals and instruction plates on the hypochlorination unit, refer to TM 5-4610-233-13&P.
e. The following illustration shows decals and instruction plates on the water tank chest.
2-38