TM 10-4610-234-13
4.15 TEE ASSEMBLY MAINTENANCE - continued.
c.
Cleaning.
(1) Wash all components with clean water and detergent.
(2) Rinse components in clean water and dry with wiping rag.
d. Inspection.
(1) Inspect male couplings (3 and 19) for cracks.
(2) Inspect female coupling (14) for cracks and damaged lock arms.
(3) Inspect tee (8) for cracks and corrosion.
e. Repair. Replace defective components. Do not reuse flange gaskets or coupling gasket.
f. Assemblv.
NOTE
Ensure gasket is fully seated in groove of coupling.
(1) Install gasket (17) in female coupling (14).
(2) Position gasket (12) and female coupling (14) on tee (8).
(3) Install eight bolts (16), flat washers (15 and 11), lockwashers (10) and nuts (9).
(4) Position male coupling (19) and gasket (18) on tee (8).
(5) Install eight bolts (20), flat washers (21 and 22), lockwashers (23) and nuts (24).
(6) Position male coupling (3) and gasket (4) on tee (8).
(7) Install eight bolts (1), flat washers (2 and 5), lockwashers (6) and nuts (7).
g. Installation. Connect tee assembly to water system (refer to para. 2.10 to connect couplings).
4-20