TM 10-4610-234-13
4.14.1
Assembly.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10
(11
(12
(13
(13
(14
(15
)
)
)
)
)
)
)
Install stem (17) in bonnet (16).
NOTE
Stem (17) has left-handed threads.
Screw disc (18) onto stem (17) all the way, making sure not to tighten more than hand tight.
Screw bonnet (16) onto valve body (19).
Install stuffing box (15) into bonnet (16).
Install new packing (14).
Install packing gland follower (13).
Screw packing gland nut (12) onto stuffing box.
Install handwheel (11) and label plate (10).
Screw handwheel nut (9) onto stem (17).
NOTE
Make sure gasket (6) is fully seated in groove of female coupler (5).
Install gaskets (6 and 8) in female coupler (5) and cap (1) .
Apply anti-sieze tape to threads of female coupler (5).
Using pipe wrench, screw female coupler (5) into valve body (19).
Connect chain (4) to female coupler (5) and plug (3).
Apply anti-sieze tape to threads of male coupler (7).
Using pipe wrench, screw male coupler (7) into valve body (19).
Connect chain (2) to male coupler (7) and cap (1).
Installation.
(1) Remove cap (1) from male coupler (7) and plug (3) from female coupler (5).
(2) Connect gate valve assembly to water system (refer to para. 2.10 to connect couplings).
4-18.2