TM 10-4610-237-12
Section II. REPAIR PARTS AND SPECIAL TOOLS LIST
4.1
COMMON TOOLS AND EQUIPMENT.
For authorized common tools and equipment, refer to the Modified Table of Organization and Equipment (MTOE), CTA
50-970 or CTA 8-100, applicable to your unit.
4.2
SPECIAL TOOLS TEST MEASUREMENT AND DIAGNOSTIC EQUIPMENT (TMDE) AND SUPPORT
EQUIPMENT.
Refer to the Maintenance Allocation Chart contained in Appendix B for maintenance tasks authorized at unit level
maintenance and the TMDE and support equipment required to perform these tasks. No special tools are required to
maintain the 20K Water Storage and Distribution System Pipe wrenches used to maintain system are supplied as part of
the accessory kit.
4.3
REPAIR PARTS.
Repair parts are listed and illustrated in the repair parts and special tools list, TM 10O4610-237-20P, covering unit
maintenance of this equipment.
Section III. SERVICE UPON RECEIPT
4.4
SITING.
4.4.1 Transport. The water system is designed to be packaged and shipped inside the triple container supplied
with the system. Transport the water system only on equipment compatible with triple container transport
requirements. Refer to the applicable TM.
4.4.2 Site Selection. When selecting a site for installation of the water system, consider the overall operating
area. Siting must include access to the main water source (TWDS), adequate space to set up the water tank and
associated hoses, and space for movement of water transport vehicles. Site should be level and provide good
water drainage away from system components. If possible, site should slope downhill from water source to water
dispensing points.
4.5
SHELTER REQUIREMENTS.
The water system does not require special sheltering during normal operation. Store unused water
system components in the triple container to prevent damage and minimize routine maintenance.
4.6
CHECKING UNPACKED EQUIPMENT.
a.
General. Except for the 20K water tank, all components of the water system are packaged and shipped in
one triple container. The 20K water tank is packaged and shipped in a water storage chest. Where possible,
save crating inside the triple container for reuse. It will make repacking easier. When uncrating the
equipment, keep in mind that the system is made up of different connection kits. This manual addresses
installation and use of all connection kits, but you may not need all of these components to perform your
mission. Your operating requirements will determine which connection kit/components are needed to
perform the mission.
4-2