SYMPTOM
Quick disconnect adapter is loose.
MALFUNCTION
Check quick disconnect adapter for looseness
CORRECTIVE ACTION
Tighten the quick disconnect adapter.
Check quick disconnect elbow gaskets for distortion or wear.
CORRECTIVE ACTION
Remove the elbow and replace the gaskets.
Check the dust cap gaskets for distortion or wear.
CORRECTIVE ACTION
Remove the dust cap and replace the gaskets.
TROUBLESHOOTING PROCEDURE
END FITTING ASSEMBLY
SYMPTOM
Tank leaks at clamping points.
MALFUNCTION
Check for loose or missing bolts on the clamps.
CORRECTIVE ACTION
Tighten all clamping bolts to 70 ± 5 ft-lbs (95 ± 7 N m).
Check for damaged clamps.
CORRECTIVE ACTION
Replace the top and/or bottom clamps (WP 0018 00).
TROUBLESHOOTING PROCEDURE
PRESSURE GAGE
SYMPTOM
Pressure gage fails to operate.