TM 10-5430-240-13&P
0015 00
0015 00-3/4 blank
CAUTIONS
Equipment operation is allowed with a minor leak, (Class I or II). When operating
with Class I or II leaks, continue to check visually and at regular intervals. Class III
and IV leaks should be repaired as soon as the equipment can be taken out of service.
Stop operation immediately if a deficiency is noticed which would damage the
equipment if operations continued.
NOTE
Within the designated interval, these checks are to be performed in the order listed.
Table 1. Unit Preventive Maintenance Checks and Services for 3,000 and
5,000 Gallon Semi-Trailer Mounted Collapsible Water Tanks.
END OF WORK PACKAGE
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE CHECKED
OR SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
1
Quarterly
Water Tank/Envelope
Inspect for cuts, punctures
and leaks. Check for loose
or missing bolts where
fittings connect to tank.
Tank envelope
is cut, punctured
or leaks. Fitting
bolts loose or
missing.
2
Quarterly
Ground Cloth
Inspect for punctures or
tears.
Ground cloth is
damaged.
3
Quarterly
Drain Assembly/Hose
Attachments
Inspect for missing
gaskets or damaged
coupling arms. Check for
leaks.
Gaskets missing
or damaged
coupling arms.
Class III leaks
present.
4
Quarterly
Filler/Discharge
Couplings and Hose
Attachments
Inspect for proper
connection, leakage, and
loose or missing gaskets.
Couplings are
damaged or
loose. Hose
fittings straining
fabric. Class III
leaks present.
5
Quarterly
Gate Valve
Check for proper operation
and/or leakage.
Gate valve will
not open/close.
Class III leaks
present.
6
Quarterly
Repair Kit
Check for missing
components.
Repair items are
missing.