TM 10-8110-202-13 & P
INSPECTION:
1. Replace damaged spring retainer (1).
2. Replace bent or distorted helical spring (2).
3. Replace spring housing (4) with damaged threads.
4. Replace guide pin (7) with damaged threads.
5. Replace bent or distorted washer (6).
6. Check adapter body (3) for damaged threads and general condition. Replace adapter body (3)
if any damage is found.
ASSEMBLY:
All adapter assembly parts must be cleaned with a mild non-
toxic detergent and assembled on a clean surface. Remember
that the adapter assembly will be used to dispense drinking
water. A dirty or contaminated adapter assembly part
could cause sickness or even death to personnel drinking
water from the drum.
1. Clean all adapter assembly parts with a mild non-toxic detergent and cleaning brush.
2. Install
3. Install
Only a new adapter gasket (5) may be used in assembly
procedures.
washer (6) onto guide pin (7).
new adapter gasket (5) onto guide pin
(7) with its chamfered edge toward the guide
pin head.
4. Thread guide pin (7) into spring housing (4)
and tighten.
5. Insert spring housing (4) into adapter body (3).
Wear eye protection when installing
the helical spring.
6. Install helical spring (2) into spring housing (4).
7. Thread spring retainer (1) into adapter body
(3). Tighten spring retainer (1) with
adjustable spanner wrench.
5-18