TM 10-8110-202-13 & PASSEMBLY/REPLACEMENT:1.2.3.4.5.6.7.8.All coupler valve parts must be cleaned with a mild non-toxic detergent and assembled on a clean surface. Re-member that the coupler valve will be used to dispensedrinking water.A dirty or contaminated coupler valvepart could cause sickness or death to personnel drinkingwater from the drum.Clean all coupler valve parts with a mild non-toxic detergentInstall valve stem (5) into valve body (1).Only new gaskets (2) andsembly procedures.Insert a new packing (8) into valve body(1) over valve stem (5).Install packing gland (7) into valve body(1) over valve stem (5).Install packing nut (6) onto valve body(1) and tighten using a 1-1/8 inch openend wrench.Install handwheel (4) onto valve stem (5).Install nut (6) onto valve stem (5) andtighten.Install two new gaskets (2) into valvebody (1).and stiff-bristle cleaning brush.packing (8) may be used in as-5-14