TM 5-3820-256-10
Table 2-7. Water/Foam Injection Preventive Maintenance Checks and Services
ITEM
INTERVAL
Item to be
Procedures
Equipment is
NO.
Inspected
Check for and have repaired
not ready/
B D A W M
or adjusted as necessary.
available if:
1
X
Reservoir
Check water level in sight glass.
Add water as required.
2
X
Foam container
Check chemical level in container.
Add chemical as required.
3
X X
Hydraulic motor
Check lines and fittings for leaks.
4
X
X
Drive belt, motor
Check for cracks and fraying.
5
X
Hydraulic oil piping
Check lines for leaks.
6
X
Water injection pump
Check lubricant level. Add as
recommended.
7
X
Foam pulse pump
Check for leaks.
Table 2-8. Force/Feed Lubricator Preventive Maintenance Checks and Services
ITEM
INTERVAL
Item to be
Procedures
Equipment is
NO.
Inspected
Check for and have repaired
not ready/
B D A W M
or adjusted as necessary.
available if:
I
X
Reservoir
Check lubricant level in sight glass.
Add lubricant as required.
2
X
Lubricator
Adjust the flow of lubricant into air
line during air drilling.
3
X
Lines and fittings
Check for leaks.
Table 2-9. Break-out Assembly Preventive Maintenance Checks and Services
ITEM
INTERVAL
Item to be
Procedures
Equipment is
NO.
Inspected
Check for and have repaired
not ready/
B D A W M
or adjusted as necessary.
available if:
1
X X
Break-out tongs
Check tong dies for dirt accumulation
or wear. Clean as required. Notify
unit maintenance for replacement.
X
Check wire rope for fraying; check
rope clips for loose nuts. Notify
unit maintenance for repair.
2
X
Hydraulic cylinder, lines
Check for leaks at hose connections.
and fittings
Check cylinder for leakage past the
piston rod.
2-29