ENGINE DIAGNOSTIC TEST PROCEDURES
Section 6
SHUTOFF CABLE/ELECTRIC SHUTOFF
400 Series On-Highway (with
Robert Bosch MW Pumps)
FROM FORM NO. CGED-365
SHUTOFF CABLE OR ELECTRIC SHUTOFF
4
ADJUSTED TO ALLOW FULL RUN POSITION
METHOD
1st CHECK
2nd CHECK
VISUAL CHECK
NOTE: If the shutoff cable is properly adjusted and
electric shutoff is properly adjusted and functional,
enter OK in 1st check block. As necessary, adjust
linkage or solenoid and indicate correction in
Comments Section.
I.
SHUTOFF CABLE (MANUAL SHUTOFF)
Visual Check
The injection pump shutoff lever is spring loaded to
the run position. With the shutoff cable pulled out to
stop the engine, the shutoff lever must contact the
shutoff screw, as shown in Figure 6.
Adjustment
To ensure that the control rack is not restricted by the
shutoff lever during engine operation, adjust the shutoff
cable so it can be attached to the shutoff lever when the
cable knob is fully sealed against the dash and the
shutoff lever is turned fully counterclockwise (Full Run
Position).
Figure 6. Shutoff Test
(466 w/Robert Bosch MW Pump)
CG ES-240-4
Printed in United States of America
Page 16