TM 5-3825-226-24
AIR CLEANER ASSEMBLY
INSTALL AIR CLEANER ASSEMBLY
1.
Install element (I) in housing (2).
2.
Put housing (2) in position on panel assembly
(3).
3.
Install nuts (4) to hold the air cleaner housing to
the panel assembly and tighten them to a torque
of 20 +±5 lb.ft. (25 ±- 7 N-m).
4.
Install element (5) in the air cleaner housing.
5.
Install cup assembly (6) and the precleaner
assembly on the air cleaner housing.
3-36