TM 5-3825-226-24AIR CLEANER HOUSING AND PANEL ASSEMBLYINSTALL AIR CLEANER HOUSING AND PANEL ASSEMBLY1.Put the air cleaner housing and panel assembly(1) in position on the machine.2.Put handle assembly (2) in position and installthe five bolts (3), the washers and one nut tohold the handle assembly.3.Install bolt (4), the washer and nut to hold thetop of the panel assembly to the hydraulic tank.4.Install the four washers and nuts (6) to hold thebottom of the panel assembly in position.5.Connect air indicator hose (5) to the air cleanerhousing and tighten the clamp to a torque of 18± 5 lb.ft. (24 ± 7 N-m).6.Connect the hose for the engine air intake andtighten clamp (7) to a torque of 18 ± 5 lb.ft. (24± 7 N-m).3-38