TM 5-3825-229-14&P4-63. SPRAY NOZZLES (cont)a.Removal.(1)Loosen two set screws (1) on ring (2).Loosen ring (2) by rotatingcounterclockwise one turn.(2)Rotate nozzle (3) counterclockwiseand remove nozzle (3) from elbow (4).b.Disassembly.(1)Remove eight screws (1).(2)Separate lower plate (2), gasket (3)and upper plate (4).c.CleaningandInspection.WARNINGWear protective goggles when using thecleaning solvent. Avoid contact with theeyes. If contact occurs, flush eyes withcold water for 5 minutes and seekimmediate medical attention. Drycleaning solvent (PD-680) is both toxicand flammable. Avoid prolongedbreathing of vapors. Avoid skin contact.Use only in a well-ventilated area.Keep away from open flame. Flashpoint of solvent is 138°F (590C).(1)Clean off upper and lower plates (2 and 4) with PD-680 solvent (Item 13, Appendix E).(2)Inspect upper and lower plates (2 and 4) for damage.dAssembly.(1)Install new gasket (3) between upper plate (2) and lower plate (4).(2) Secure plates (2 and 4) and gasket (3) with screws (1).4-145
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business