4-45. FUEL STRAINER REPLACEMENT (CONT).
(1)
Place suitable container under strainer (1).
WARNING
Fuel is very slippery and can cause
falls. To avoid injury, wipe up spilled
fuel with rags.
NOTE
Cap each hose after removal.
(2)
Loosen two clamps (2 and 3) and remove two
hoses (4 and 5) from strainer (1).
(3)
Remove suitable container and dispose of fuel in
accordance to local regulations.
b. Cleaning/Inspection.
(1)
Wipe off strainer and hoses with lint-free cloth.
WARNING
·
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective
goggles and gloves; use only in a well-ventilated area; avoid contact with skin,
eyes, and clothes and do not breathe vapors. Keep away from heat or flame.
Never smoke when using solvent; the flash point for type I drycleaning solvent
is 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result in
injury or death to personnel. P-D-680 type III is a substitute for types I and II in
this application. The flash point for type III is 200°F (93°C).
·
If personnel become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts skin or clothes, flush with cold water.
If solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
(2)
Flush strainer with drycleaning solvent and inspect flow. If flow is inhibited, replace strainer.