TM 5-3895-370-14&P
Table 2-1. Controls and Indicators - CONT.
Key
Control/Indicator
Function
11
Throttle Control
Controls engine speed. When knob is turned to desired speed, button is pushed
down to lock in speed.
12
Pump Transmission
Controls flow of hydraulic system to provide spray or suckback operations.
Control Lever
Lever has three positions: Full forward (FWD) places system in operation, center
position places system in neutral, and full backward (REV) places system in reverse.
13
Pump Tachometer (Flow
Indicates gallons pumped per minute. Maximum rate is 350 gallons per
Indicator Rate)
minute (GPM).
14
Right Raise/Lower
Controls the raising or lowering of the right side of spraybar.
Lever
15
Left Raise/Lower
Controls the raising or lowering of the left side of spraybar.
Lever
16
Right/Left Shift Lever
Controls the left/right shifting of spraybar.
17
Spraybar On/Off Lever
Opens/closes gate valve to allow material to flow from spraybar.
18
Flow Rate Indicator
Provides power to the flow rate indicator (13).
Switch
19
Flow Rate Indicator
Illuminates to indicate flow rate indicator switch (18) is on.
Light
2-3