B - Before
D - During
A - After
W - Weekly
M - Monthly
Item
Interval
Item to Be
Procedure
Check for and have repaired or
Equipment is Not
Ready/Available
No.
B D A W M
Inspected
adjusted as necessary
If:
TM 5-3895-370-14&P
2-8. OPERATOR PMCS TABLE.
Table 2-2. Operator Preventive Maintenance Checks and Services
NOTE:
Within designated interval, these checks are to be performed in the order listed.
GENERAL
1
Walk Around
a.
Check for obvious damage.
a.
Damage that impairs
Inspection
mission.
b.
Check for leaks.
b.
Class III leak detected.
c.
Check electrical wiring for cuts,
c.
Wires cut or broken.
breaks, or loose connections.
d.
Check that all data plates are
readable and undamaged while
performing BEFORE checks.
FRONT OF
DISTRIBUTOR
2
Jackstand
Check jackstand for proper
Jackstand has cracks or does
operation, dents, and cracks.
not operate properly.
WARNING
Battery acid (electrolyte) is
extremely harmful. Always
wear safety goggles and
rubber gloves, and do not
smoke when performing
maintenance on battery.
Injury will result if acid
contacts skin or eyes.
3
Batteries,
a.
Visually inspect batteries for a
a.
Battery or terminal posts
Cables, and
cracked or leaking casing or
damaged.
Terminals
broken or burned terminal posts.
b.
Check cables for damage and
b.
Cables cut, torn or frayed or
terminals for damage or
terminals damaged.
looseness (para 3-9).
4
Battery Fluid
Remove cell covers and check the
Batteries will not crank engine.
Level
electrolyte level of each cell.
Electrolyte should reach the level
of the split rings (para 3-9).
2-8