2-2. LOCATION AND USE OF CONTROLS AND INDICATORS (CONT).
Table 2-1. Controls and Indicators - CONT.
Key
Control/Indicator
Function
20
Valve #1 (V1)
Controls flow of material through spraybar. Valve #1 is the main operating valve
and has three positions: T (tank), B (bar), P (pump) depending on the desired
operation (shown in Tank position).
21
Valve #2 (V2)
Controls flow of material from source to pump. Valve #2 has two positions:
open and closed (shown closed).
22
Valve #3 (V3)
Controls suckback of material through/from spraybar. Valve #3 has two positions:
open and closed (shown closed).
23
Valve #4 (V4)
Controls flushing the pump and spraybar. Valve #4 has two positions: open and
closed (shown closed).
24
Valve #5 (V5)
Controls flushing the pump and spraybar and circulates material through spray bar.
Valve #5 has two positions: open and closed (shown closed).
25
Valve #6 (V6)
Allows flow of material through hand spray. Valve #6 has two positions: open and
closed (shown closed).