TM 5-3895-370-14&P(3)Remove two screws (7), nuts (8), and reducer(6) from console (9).(4)Remove nut (10), lockwasher (11), and groundlead (12) from reducer (6). Discard lockwasher.(5)Remove three fuses (13) from voltage reducer(6).b. Installation.(1)Install three fuses (13) in voltage reducer (6).(2)Install ground lead (12), lockwasher (11), andnut (10) on reducer (6).(3)Install reducer (6) on console (9) with twoscrews (7) and nuts (8).4-191