TM 5-3895-370-14&P(3)Remove nipple (4) from relay valve (3).(4)Remove three elbows (6 and 7) from relay valve(3).b. Installation.WARNINGAdhesive sealant, MIL-S-46163, candamage your eyes. Wear safetygoggles/glasses when using; avoidcontact with eyes. If sealant contactseyes, flush eyes with water and getimmediate medical attention.NOTEApply sealing compound to threadsof all fittings that go on relay valveand air tank prior to installation.(1)Install three elbows (6 and 7) and nipple (4) onrelay valve (3).(2)Install nipple (4) and relay valve (3) on air tank(5).(3)Install three hoses (2) on relay valve (3).Tighten fittings (1).END OF TASK4-277