TM 5-3895-370-14&P
(3)
Remove nipple (4) from relay valve (3).
(4)
Remove three elbows (6 and 7) from relay valve
(3).
b. Installation.
WARNING
Adhesive sealant, MIL-S-46163, can
damage your eyes. Wear safety
goggles/glasses when using; avoid
contact with eyes. If sealant contacts
eyes, flush eyes with water and get
immediate medical attention.
NOTE
Apply sealing compound to threads
of all fittings that go on relay valve
and air tank prior to installation.
(1)
Install three elbows (6 and 7) and nipple (4) on
relay valve (3).
(2)
Install nipple (4) and relay valve (3) on air tank
(5).
(3)
Install three hoses (2) on relay valve (3).
Tighten fittings (1).
END OF TASK
4-277