TM 5-3895-370-14&P
4-104. AIR RATIO RELAY VALVE REPLACEMENT (CONT).
(3)
Remove nipple (6) from air ratio relay valve (5).
(4)
Remove fitting (8), tee (9), and three elbows (10
and 11).
b. Installation.
WARNING
Adhesive sealant, MIL-S-46163, can
damage your eyes. Wear safety
goggles/glasses when using; avoid
contact with eyes. If sealant contacts
eyes, flush eyes with water and get
immediate medical attention.
NOTE
Apply sealing compound to threads
of all fittings that go on ratio relay
valve
and
air
tank
prior
to
installation.
(1)
Install three elbows (10 and 11), tee (9), and
fitting (8) on air ratio relay valve (5).
(2)
Install nipple (6) on air ratio relay valve (5).
(3)
Install nipple (6) and air ratio relay valve (5) and
on air tank (7).
(4)
Install six hoses (1) on air ratio relay valve (2).
Tighten fittings (1).
END OF TASK
4-280