TM 5-3895-370-14&P
4-126.
TOOL BOX REPLACEMENT/REPAIR (CONT).
WARNING
·
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective
goggles and gloves; use only in a well-ventilated area; avoid contact with skin,
eyes, and clothes and do not breathe vapors. Keep away from heat or flame.
Never smoke when using solvent; the flash point for type I drycleaning solvent
is 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result in
injury or death to personnel. P-D-680 type III is a substitute for types I and II in
this application. The flash point for type III is 200°F (93°C).
·
If personnel become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts skin or clothes, flush with cold water.
If solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
·
Adhesive causes immediate bonding on contact with eyes, skin, or clothing
and also gives off harmful vapors. Wear protective goggles and used in well-
ventilated area. If adhesive gets in eyes, try to keep eyes open; flush eyes with
water for 15 minutes and get immediate medical attention.
(2)
Inspect foam insulation for tears or other significant damage. If damaged, replace by scraping off old foam and
cleaning the area with drycleaning solvent. Apply adhesive to the clean area and install new foam insulation.
d.
Assembly.
(1)
Install hasp (28) on gage box (17) with two screws (27), lockwashers (26), and nuts (25).
(2)
Install cover (23) on gage box (17) with three screws (23), lockwashers (22) and nuts (21).
4-328