TM 5-3895-370-14&P4-139. HYDRAULIC FLUID COOLER REPLACEMENT (CONT).(3)Remove plugs from cooler coil and flush coolercoil with clean hydraulic oil. Inspect for leaks.(4)Inspect all parts for rust, cracks, and wear.(5)Replace all parts failing inspection.(6)Install plugs in cooler coil.d.Assembly.Install screen (5) on cooler coil (6) withtwo angle brackets (4), four u-bolts (3), eightwashers (2), and 16 nuts (1).e. Installation.(1)Install cooler assembly (1) on radiator support(7) with four screws (6), washers (5),lockwashers (4), and nuts (3).WARNINGAdhesive sealant, MIL-S-46163, candamage your eyes. Wear safetygoggles/glasses when using; avoidcontact with eyes. If sealant contactseyes, flush eyes with water and getimmediate medical attention.NOTE·Remove plugs and caps prior toinstalling hoses.·Apply hydraulic sealant to hosethreads.(2)Install two hoses (2) on cooler assembly (1).NOTEFollow-on maintenance: Install rearfan guard (para 4-54).END OF TASK4-370