TM 5-3895-370-14&P
WARNING
System is under extreme pressure
and high temperature. Ensure that
locking levers are fully engaged and
secured with the locking wire or
severe injury or death to personnel
may occur.
(7)
Close locking levers (8) on hose end (7).
NOTE
Needle-nose pliers may be necessary
to insert locking ring.
(8)
Insert locking ring (9) through locking
levers (8).
c.
Disconnecting Hoses from Fitting/Ports.
NOTE
Needle-nose pliers may be necessary to remove locking ring.
(1)
Remove locking ring (9) from locking levers (8). Open locking levers (8).
WARNING
Always use an assistant when disconnecting bituminous hoses that are hot or
filled with bituminous material or serious injury to personnel may result.
NOTE
Place a suitable container beneath hose fittings before disconnecting to collect all
bituminous material. Contact your local environmental office or support
installation for proper disposal.
(2)
With the aid of an assistant, remove hose
end (7) from nipple (4). Allow bituminous
material to drain completely from hose.
NOTE
Always replace dust covers or caps
on hoses or pipes when work is
finished with them.
(3)
Install dust cover (6) on hose end (7).
(4)
Install dust cover (3) on nipple (4) on inlet
and/or outlet port (5).
2-31