TM 5-3895-370-14&P
2-14. ENGINE OPERATING PROCEDURES (CONT).
(2)
Turn key switch (3) on gage panel (4) fully
to the right.
(3)
Depress reset button (5) and start button
(6) at the same time.
(4)
Once engine starts, release start button
(6) while continuing to depress reset
button (5).
(5)
Allow engine to idle for 30 seconds while
holding reset button (5) down.
CAUTION
If
engine
oil
pressure
has
not
reached 10 psi (69 kPa) after 60
seconds
of
operation,
shutdown
distributor by turning key switch fully
to the left (counterclockwise) and
notify unit maintenance.
NOTE
If reset button is released before
engine oil pressure reaches 10 psi
(69 kPa), engine will stall.
(6)
When oil pressure gage (7) has reached
10 psi (69 kPa), release reset button (5).
(7)
Allow engine to idle at 1200 RPM for
approximately 5 minutes.
(8)
Ensure that engine will run up to 2100
RPM by temporarily turning throttle control
(8) on control console (2) then return
engine RPM to 1200.
(9)
Perform
operator
PMCS
procedures
designated During in the Interval column
(Table 2-2).
(10)
Turn flow rate indicator light switch (9) to
ON.
b.
Engine Shutdown. Turn key switch (3) on
gage panel (4) fully to the left (counterclockwise).
2-28