TM 5-3895-370-14&P
4-149. RATE INDICATOR REPLACEMENT (CONT).
(3)
Remove mounting clip (6), rate indicator (3) and
gasket (7) from console (8).
b.
Assembly.
(1)
Install
gasket
(7),
rate
indicator
(3),
and
mounting clip (6) to console (8).
(2)
Install two cage nuts (5) and screws (4) to
mounting clip (6). Tighten screws (4).
(3)
Install resistor (2) and seven leads (1) to
indicator (3).
NOTE
Follow-on maintenance:
·
Install console rear panel (para 4-
153).
·
Connect negative battery cable
(para 4-84).
END OF TASK