TM 5-4320-301-13&P
TM 08936A-13&P/1
Section III
DIRECT MAINTENANCE PROCEDURES (Contd.)
5-6.
NOZZLE DISTRIBUTION ASSY, REPAIR (Contd.)
b.
Inspect all parts for cracks, wear, and damage.
c.
Replace all packings and unserviceable parts.
INSTALLATION
a
Install nozzle spout (21) and adapter (20) on body (11).
b.
Using adjustable wrench, tighten locknut (19) snugly against body (11) ensuring spout (21) is properly positioned.
c.
Install dustcap (18) drawbar (17) spring (16) and chain (15).
d.
Using common pliers, install two retaining links (14) and squeeze ends shut until they are just touching.
e.
Wrap end of adapter (13) with one layer of teflon tape ST410.
f.
Using adjustable wrench install adapter (13) into body (11). Tighten snugly against body.
Change 8 5-7