TM 5-4320-301-13&PTable 5-1. Troubleshooting (Cont'd.)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION2. NOZZLE DISTRIBUTION ASSYStep 1. Inspect for damaged or missing protective cap, chain, or spring.Replace with serviceable protective cap, chain, and spring. Refer to direct maintenanceprocedures 5-6.Step 2. Inspect for cracked or damaged female quick-disconnect reducer.Replace with serviceable female quick-disconnect reducer. Refer to direct maintenanceprocedures 5-6.Step 3. Inspect for damaged swivel.Replace with serviceable swivel. Refer to direct maintenance procedures 5-6.Step 4. Inspect for damaged control or nozzle.Replace with serviceable nozzle. Refer to direct maintenance procedures 5-6.5 - 2