TM 5-4610-228-13
TM 08846A-13/1
4-15. NOZZLE STAND ASSY/REPAIR (CONT).
LOCATION/ITEM
ACTION
REMARKS
INSTALLATION
a. Install two legs (5) in clevis leg (3) inserting clevis
pins (4) through holes in clevis.
b. Install two cotter pins (6) and bend back around
heads so they will not snag on clothing or hoses.
c. Install new or repaired sash chains (2) with s-hooks
(1) to stand legs (3) and (5).
d. Bend s-hook inward with a pair of common pliers and
return stand to service.
e. Install stand assy back in system.
4-18