TM 5-4610-228-13
TM 08846A-13/1
S e c t i o n V I . P R E P A R A T I O N F O R S T O R A G E F O R S H I P M E NT
4-17. DISASSEMBLY AND REPACKAGING
Disassemble this system in reverse order of assembly. Perform the following prior to repackaging:
a.
b.
c.
d.
e,
Drain, dry, and then cap and plug all hose assys.
Drain and dry all metal assys, such as valve and tee assys. Cap and plug these items, as applicable.
Remove and retain the two quick-disconnect elbows from the suction and discharge side port nipples on
the top of each of the water storage and dispensing tanks. Then, attach a protective cap to each of these
two nipples.
Drain each tank by turning the gate wheel on the drain hose assy, which is attached to the drain fitting
in the tank bottom. Then, remove the drain hose assy and thread the protective plug into the tank drain
fitting.
Drain, collapse and fold each of the tanks.
NOTE
The tanks are now ready to be placed in suitable carrier or container.
f. Remove drain plug on 125-CPM and 350 GPM pumps and engine assys, drain water from pumps.
Install drain plug after water has been drained from Pumps.
g. Scrub inside of 36-gallon water bag with water chlorine solution.
Use one ampule-tube of calcium
hypochlorite (NSN 6810-00-266-6979) for each gallon of water. Rinse bag several times with potable
water and dry completely. Fold bag compactly and store in dry, clean place. For short-term storage, it
is best to hang bag up for drying after each field use.
h. All components placed in a Tricon container must be blocked and braced
Change 2 4-19/(4-20 Blank)