TM 5-5430-211-13 & P
3-13
VENT ASSEMBLY-CONTINUED
ITEM
ACTION
REMARKS
INSTALLATION-CONTINUED
2-Continued
Replace washers (7) and bolts
(6). Tighten the bolts evenly but
finger tight only.
If the bolts are not
tightened evenly the
coupling will not be
parallel to the
compression rings and
water will leak from the
joint.
Torque the bolts down to 40 in.-
lbs. in the sequence shown.
Torque the bolts down to 100
in.-lbs. in the sequence shown.
DO NOT OVER TIGHTEN.
3-26