TM 5-5430-211-13 & P3-13 VENT ASSEMBLY-CONTINUEDITEM ACTION REMARKSINSTALLATION-CONTINUED2-ContinuedReplace washers (7) and bolts(6). Tighten the bolts evenly butfinger tight only.If the bolts are nottightened evenly thecoupling will not beparallel to thecompression rings andwater will leak from thejoint.Torque the bolts down to 40 in.-lbs. in the sequence shown.Torque the bolts down to 100in.-lbs. in the sequence shown.DO NOT OVER TIGHTEN.3-26