c .
d.
f.
9 .
h.
i.
Attach drain and gate valve to drain connection. Unfold tank
envelope to lie flat in original position. Valve should extend
from bottom of tank.
Check that valve is closed.
Remove dust caps and dust plugs from tank vent assembly, elbows,
hose and valve assembly.
If the sealing surfaces of the couplings
are dirty,
wipe with a clean cloth.
Connect vent assembly to tank Model 53029A-20. Close both arms
at the same time by hand.
Do not close cam arms one at a time,
as this tends to cause misalignment of the mating parts and
prevents cam arms from closing properly. Model 53029B20 screw
on vent assembly to stand pipe.
Connect filler/discharge elbows to tank. Close both cams arms on
each assembly at the same time by hand.
Select the filler/discharge elbow to be used in operation. Place
dust cap or plug on the filler/discharge elbow that will not be
used.
Connect hose to elbow.
Close both cam arms at the same time by
hand. (4 IN. filler/discharge hose is not supplied with tank).
Connect valve to hose.
Close both cam arms at the same time by
hand.
Close the gate valve.
2-6
Change 1